Smith Flashback Arrestors Torch to Hose
Features
All the details- Protects the hosesFitted at the torch, the arrestors stop a flashback before it can travel back into the oxygen or fuel hose.
- Check valve and flame arrestor in oneThe check valve keeps gas from running backwards, and the sintered stainless steel element puts out the flame.
- A matched pairOne oxygen unit with a green band and one fuel-gas unit with a red band, threaded in opposite directions so they can't be swapped.
- Standard B fittings, 9/16"-18For torch handles with male B inlets.
- Nothing to resetBrass bodies with no manual reset, UL Listed.
A pair of Smith flashback arrestors that screw onto a torch handle's gas inlets, so the hoses connect to the arrestors rather than straight to the torch. Each unit has a built-in check valve that blocks gas flowing backwards and a stainless steel flame stop that halts a flashback before it can enter the hose. It suits torch handles with standard male B inlets; THE LITTLE TORCH, with its hoses fixed to the handpiece, takes our regulator-mount pair instead.
| Maker | Smith Equipment (Miller) |
|---|---|
| Model | H743, torch mount |
| In the set | 2: oxygen (green band) and fuel gas (red band) |
| Mounting | On the torch handle's gas inlets; the hose connects to the arrestor |
| Fittings | B size, 9/16"-18: oxygen right-hand, fuel left-hand |
| Construction | Brass body, sintered stainless steel flame arrestor, built-in check valve |
| Listing | UL Listed |
| Made in | USA |
Sold as
Each: one pair: an oxygen arrestor and a fuel-gas arrestor. Torch, hoses and regulators are sold separately.
Good to know
- Using THE LITTLE TORCH? Its hoses are crimped to the handpiece, so there is no torch inlet for this pair to fit. Choose our Smith Flashback Arrestors Regulator to Hose, which mount at the regulators.
- Check your torch's inlets first: this pair needs male B (9/16"-18) inlets. Our Melting Torch takes A-size hose fittings and THE HOKE TORCH takes plain rubber tubing, so neither accepts it directly.
- Expect a pressure drop: the arrestors restrict the flow noticeably, so you may need to turn the regulator up to keep the same flame.
- Fit them by hand first: start each nut with your fingers, then snug it with a spanner without forcing it, because brass threads strip easily. Never put oil, grease, tape or sealant on the fittings.
- Replace after a flashback: there's no manual reset, but a unit that has stopped a flashback must be replaced.
For oxy-fuel torches, keep all fittings free of oil and grease, and leak-test every connection before lighting. Never run acetylene above 15 psi. Replace any arrestor that has stopped a flashback. Ships without gas, as non-hazardous goods.