Reliable 8000CJ Steam Cleaner, 4.5 L, Unlimited Steam
Features
All the details- Unlimited continuous steamFed from a direct water line instead of a fixed tank you refill by hand — no waiting for the boiler to re-pressurize.
- Automatic pump shutoffIf the water supply is interrupted, on top of the range's usual 4 safety systems: a pressure switch, thermostat protection, a safety cap with a built-in relief valve, and a low-water light.
- Up to 58 psi (4 bar)Of steam pressure.
- Stainless steel throughoutTank and outer casing — with a pressure gauge, foot pedal and adjustable feet.
- Backed for 2 yearsOn the boiler tank, 1 year on the rest of the unit.
Reliable's 8000CJ is a stainless-steel, foot-pedal steam cleaner for the bench that connects to a direct water line: its 4.5 L boiler is topped up continuously instead of refilled by hand, for unlimited steam through a busy day. Made for Reliable Corporation of Toronto.
Choosing a Reliable steam cleaner
| Model | Boiler | Pressure | Continuous steam | Control | Eco mode |
|---|---|---|---|---|---|
| 4100CJ | 2.2 L (0.58 US gal) | 50 psi (3.5 bar) | up to 4 h | Side switch, no pedal, no gauge | Yes |
| 5100CJ | 2.2 L (0.58 US gal) | 50 psi (3.5 bar) | up to 4 h | Foot pedal, pressure gauge | Yes |
| 6000CJ | 4.5 L (1.25 US gal) | 60 psi (4.1 bar) | up to 6 h | Foot pedal, pressure gauge | No |
| 8000CJ (this one) | 4.5 L (1.2 US gal) | 58 psi (4 bar) | Unlimited, from a direct water line or the tank | Foot pedal, pressure gauge | No |
| 9000CJ | 4.5 L (1.25 US gal) + 2 US gal (7.6 L) container | 58 psi (4 bar) | Unlimited, from a direct water line or the container | Foot pedal, pressure gauge | No |
All five are Reliable models we sell. The 8000CJ and 9000CJ trade the fixed boiler on the three smaller models for an unlimited direct water-line supply; the 9000CJ adds a 2 US gal container as a backup to the water line.
Works with
| Maker | Reliable Corporation |
|---|---|
| Model | 8000CJ |
| Boiler capacity | 4.5 L (1.2 US gal), continuously fed from a direct water line |
| Operating pressure | 58 psi (4 bar) |
| Steam temperature | 221 °F (105 °C) |
| Heat-up time | about 20 minutes from cold to full working pressure |
| Continuous steam | Unlimited, from a direct water line |
| Water connection | 1/4 in (6.4 mm) inside-diameter tubing (clear tubing recommended) to the boiler's water inlet, secured with an SAE size 4 hose clamp; supply pressure 50 psi (3.4 bar) maximum; tap water only, not distilled |
| Heating element | 1,200 W |
| Electrical supply | 120 V, 60 Hz, 10 A; a dedicated 20 A circuit is recommended |
| Safety systems | Pressure switch, thermostat protection, safety cap/relief valve, low-water light, automatic pump shutoff if the water supply is interrupted |
| Certifications | cETLus |
| Size | about 28 x 58.5 x 29 cm (11 x 23 x 11.5 in) |
| Weight | about 11.7 kg (26 lb) |
| Warranty | 2 years on the boiler tank, 1 year on the rest of the unit |
| Made in | Italy |
Sold as
Each: the 8000CJ unit, foot pedal, power cord and adjustable steam nozzle. Not included: cleaning solution, a stand, or the fittings to connect it to a water line.
Good to know
- Needs a direct water-line connection before use, unlike the fixed-boiler 4100CJ/5100CJ/6000CJ — have a plumber run a supply line to the boiler's water inlet with 1/4 in (6.4 mm) inside-diameter tubing (clear tubing recommended), secured with an SAE size 4 hose clamp, and keep the breather valve closed when running on a direct line. Supply pressure must not exceed 50 psi (3.4 bar), or the pump stops.
- No manual refills. The boiler draws continuously from the water line, so it suits a bench that steams often through the day. Use tap water only, not distilled, and close the water tap when the unit is not in use. It takes about 20 minutes to reach full working pressure from cold.
- Don't steam opals or other soft, porous stones, cracked stones, or stones straight from the cold — let them reach room temperature first. This applies to any steam cleaner, not just this one.
- The safety cap is also the relief valve — treat it as a safety part, and use the blow-down valve to depressurize and drain the boiler for cleaning or storage.
- Descale periodically with a steam-cleaner additive to cut down on mineral buildup, especially in hard-water areas.
This unit produces live steam from a pressurized boiler that is fed continuously from a water line. Keep clear of the steam line and do not touch the fittings while the unit is in use. The safety cap also serves as a pressure-relief valve, so treat it as a safety part. The pump shuts off automatically if the water supply is interrupted. Let the unit cool before you check it. No chemical hazard.