{"product_id":"reliable-8000cj-steam-cleaner","title":"Reliable 8000CJ Steam Cleaner, 4.5 L, Unlimited Steam","description":"\u003cp\u003eReliable's 8000CJ is a stainless-steel, foot-pedal steam cleaner for the bench that connects to a direct water line: its 4.5 L boiler is topped up continuously instead of refilled by hand, for unlimited steam through a busy day. Made for Reliable Corporation of Toronto.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eUnlimited continuous steam,\u003c\/b\u003e fed from a direct water line instead of a fixed tank you refill by hand — no waiting for the boiler to re-pressurize.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eAutomatic pump shutoff\u003c\/b\u003e if the water supply is interrupted, on top of the range's usual 4 safety systems: a pressure switch, thermostat protection, a safety cap with a built-in relief valve, and a low-water light.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eUp to 58 psi (4 bar)\u003c\/b\u003e of steam pressure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eStainless steel throughout\u003c\/b\u003e — tank and outer casing — with a pressure gauge, foot pedal and adjustable feet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eBacked for 2 years\u003c\/b\u003e on the boiler tank, 1 year on the rest of the unit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003ctable\u003e\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMaker\u003c\/th\u003e\n\u003ctd\u003eReliable Corporation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eModel\u003c\/th\u003e\n\u003ctd\u003e8000CJ\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eBoiler capacity\u003c\/th\u003e\n\u003ctd\u003e4.5 L (1.2 US gal), continuously fed from a direct water line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eOperating pressure\u003c\/th\u003e\n\u003ctd\u003e58 psi (4 bar)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSteam temperature\u003c\/th\u003e\n\u003ctd\u003e221 °F (105 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeat-up time\u003c\/th\u003e\n\u003ctd\u003eabout 20 minutes from cold to full working pressure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eContinuous steam\u003c\/th\u003e\n\u003ctd\u003eUnlimited, from a direct water line\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWater connection\u003c\/th\u003e\n\u003ctd\u003e1\/4 in (6.4 mm) inside-diameter tubing (clear tubing recommended) to the boiler's water inlet, secured with an SAE size 4 hose clamp; supply pressure 50 psi (3.4 bar) maximum; tap water only, not distilled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eHeating element\u003c\/th\u003e\n\u003ctd\u003e1,200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eElectrical supply\u003c\/th\u003e\n\u003ctd\u003e120 V, 60 Hz, 10 A; a dedicated 20 A circuit is recommended\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSafety systems\u003c\/th\u003e\n\u003ctd\u003ePressure switch, thermostat protection, safety cap\/relief valve, low-water light, automatic pump shutoff if the water supply is interrupted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eCertifications\u003c\/th\u003e\n\u003ctd\u003ecETLus\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eSize\u003c\/th\u003e\n\u003ctd\u003eabout 28 x 58.5 x 29 cm (11 x 23 x 11.5 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eabout 11.7 kg (26 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eWarranty\u003c\/th\u003e\n\u003ctd\u003e2 years on the boiler tank, 1 year on the rest of the unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\"\u003eMade in\u003c\/th\u003e\n\u003ctd\u003eItaly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\u003c\/table\u003e\n\u003ch3\u003eChoosing a Reliable steam cleaner\u003c\/h3\u003e\u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eBoiler\u003c\/th\u003e\n\u003cth\u003ePressure\u003c\/th\u003e\n\u003cth\u003eContinuous steam\u003c\/th\u003e\n\u003cth\u003eControl\u003c\/th\u003e\n\u003cth\u003eEco mode\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e4100CJ\u003c\/td\u003e\n\u003ctd\u003e2.2 L (0.58 US gal)\u003c\/td\u003e\n\u003ctd\u003e50 psi (3.5 bar)\u003c\/td\u003e\n\u003ctd\u003eup to 4 h\u003c\/td\u003e\n\u003ctd\u003eSide switch, no pedal, no gauge\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5100CJ\u003c\/td\u003e\n\u003ctd\u003e2.2 L (0.58 US gal)\u003c\/td\u003e\n\u003ctd\u003e50 psi (3.5 bar)\u003c\/td\u003e\n\u003ctd\u003eup to 4 h\u003c\/td\u003e\n\u003ctd\u003eFoot pedal, pressure gauge\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6000CJ\u003c\/td\u003e\n\u003ctd\u003e4.5 L (1.25 US gal)\u003c\/td\u003e\n\u003ctd\u003e60 psi (4.1 bar)\u003c\/td\u003e\n\u003ctd\u003eup to 6 h\u003c\/td\u003e\n\u003ctd\u003eFoot pedal, pressure gauge\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8000CJ (this one)\u003c\/td\u003e\n\u003ctd\u003e4.5 L (1.2 US gal)\u003c\/td\u003e\n\u003ctd\u003e58 psi (4 bar)\u003c\/td\u003e\n\u003ctd\u003eUnlimited, from a direct water line or the tank\u003c\/td\u003e\n\u003ctd\u003eFoot pedal, pressure gauge\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9000CJ\u003c\/td\u003e\n\u003ctd\u003e4.5 L (1.25 US gal) + 2 US gal (7.6 L) container\u003c\/td\u003e\n\u003ctd\u003e58 psi (4 bar)\u003c\/td\u003e\n\u003ctd\u003eUnlimited, from a direct water line or the container\u003c\/td\u003e\n\u003ctd\u003eFoot pedal, pressure gauge\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003ci\u003eAll five are Reliable models we sell. The 8000CJ and 9000CJ trade the fixed boiler on the three smaller models for an unlimited direct water-line supply; the 9000CJ adds a 2 US gal container as a backup to the water line.\u003c\/i\u003e\u003c\/p\u003e\n\u003ch3\u003eSold as\u003c\/h3\u003e\u003cp\u003eEach: the 8000CJ unit, foot pedal, power cord and adjustable steam nozzle. Not included: cleaning solution, a stand, or the fittings to connect it to a water line.\u003c\/p\u003e\n\u003ch3\u003eGood to know\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cb\u003eNeeds a direct water-line connection\u003c\/b\u003e before use, unlike the fixed-boiler 4100CJ\/5100CJ\/6000CJ — have a plumber run a supply line to the boiler's water inlet with 1\/4 in (6.4 mm) inside-diameter tubing (clear tubing recommended), secured with an SAE size 4 hose clamp, and keep the breather valve closed when running on a direct line. Supply pressure must not exceed 50 psi (3.4 bar), or the pump stops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eNo manual refills.\u003c\/b\u003e The boiler draws continuously from the water line, so it suits a bench that steams often through the day. Use tap water only, not distilled, and close the water tap when the unit is not in use. It takes about 20 minutes to reach full working pressure from cold.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDon't steam opals or other soft, porous stones, cracked stones, or stones straight from the cold\u003c\/b\u003e — let them reach room temperature first. This applies to any steam cleaner, not just this one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eThe safety cap is also the relief valve\u003c\/b\u003e — treat it as a safety part, and use the blow-down valve to depressurize and drain the boiler for cleaning or storage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cb\u003eDescale periodically\u003c\/b\u003e with a steam-cleaner additive to cut down on mineral buildup, especially in hard-water areas.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSafety\u003c\/h3\u003e\u003cp\u003eThis unit produces live steam from a pressurized boiler that is fed continuously from a water line. Keep clear of the steam line and do not touch the fittings while the unit is in use. The safety cap also serves as a pressure-relief valve, so treat it as a safety part. The pump shuts off automatically if the water supply is interrupted. Let the unit cool before you check it. No chemical hazard.\u003c\/p\u003e\n\u003ch3\u003eWorks with\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\u003ca href=\"\/products\/reliable-boiler-safety-cap-gasket\"\u003eReliable Steam Cleaner Replacement Boiler Cap \u0026amp; Gasket\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/steam-cleaner-additive\"\u003eSteam Cleaner Additive\u003c\/a\u003e\u003c\/li\u003e\n\u003cli\u003e\u003ca href=\"\/products\/ultrasonic-steamer-strainer\"\u003eUltrasonic \u0026amp; Steamer Strainer\u003c\/a\u003e\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Reliable","offers":[{"title":"Default Title","offer_id":44503296409678,"sku":"49-419","price":2899.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0767\/6051\/4638\/files\/8426-1793846423821-reliable-8000cj-steam-cleaner-1-studio.png?v=1793847203","url":"https:\/\/www.europeandesign.ca\/products\/reliable-8000cj-steam-cleaner","provider":"European Design","version":"1.0","type":"link"}