Foredom H.MH-150 Brushless Highspeed Rotary Handpiece
Features
All the details- Brushless and sealedNo carbon brushes to replace, in a housing that keeps grinding dust out and keeps noise and vibration down.
- Speed with torque at both ends1,000 to 50,000 rpm on the K.1050 control, with high torque low down for setting and milling and a smooth top end for bright-cutting, finishing and polishing.
- Twist-lock colletTurn the front of the handpiece to open or close it, with no key or wrench for a bur change.
- Light in the hand6.3 in (160 mm) long, 0.75 in (19 mm) at the grip and 8.4 oz (238 g), on ceramic ball bearings.
- Replaceable cordUnscrew the rear cover and the motor cord comes away, so a worn cord doesn't retire the motor.
Foredom's H.MH-150 is the brushless rotary handpiece from its K.1050 micromotor kit, sold on its own as a spare or second handpiece. It runs up to 50,000 rpm with up to 10 oz-in (70 mNm) of torque, holds its power at low speed, and has no carbon brushes to wear out. It comes with the 3/32" (2.35 mm) collet fitted and needs a K.1050-type control box to run.
| Maker | Foredom Electric Company |
|---|---|
| Model | H.MH-150 brushless rotary handpiece, 3/32" (2.35 mm) collet |
| Speed | Up to 50,000 rpm (1,000-50,000 rpm on the K.1050 control box) |
| Torque | 10 oz-in (70 mNm) maximum |
| Motor | Brushless, sealed housing, ceramic ball bearings; 32 V DC, 3.4 A |
| Length | 6.3 in (160 mm) |
| Diameter | 0.75 in (19 mm) at the grip, 1.06 in (27 mm) at the motor |
| Weight | 8.4 oz (238 g) |
| Collet | 3/32" (2.35 mm) Foredom HP4-117 fitted; 1/8" (HP4-117B) and 3 mm (HP4-117C) also fit |
| Runs on | The control box of Foredom's K.1050, K.1053, K.1054 and K.1055 kits; not the HP4-917 brush-type control |
| Warranty | Foredom 90-day limited warranty against defects in material and workmanship, from the date of purchase; does not cover damage from accident, abuse or misuse, or ordinary wear |
Sold as
Each: the handpiece with its motor cord and the 3/32" (2.35 mm) collet fitted. No control box, foot pedal or handpiece cradle.
Good to know
- Check your control box: the H.MH-150 plugs into the brushless port at the back of the K.1050's control box (and runs on the K.1053, K.1054 and K.1055 kits, which include it). It won't run on Foredom's HP4-917 control, and it isn't the K.1040's or K.1060's handpiece: those kits use the H.MH-140 and H.MH-160.
- Spare collets: current handpieces (serial 811xxxx and up) take Foredom's HP4-117 collets in 3/32" (2.35 mm), 1/8" or 3 mm. Handpieces numbered 807xxxx or lower need Foredom's older HP7-500x collets, and the HP6-117 collets made for the H.MH-140 and H.MH-160 don't fit.
- Changing a bur: switch the motor off, twist the front toward R until it clicks open, push the shank about 1-1/8 in (29 mm) in, all the way to the bottom, then twist toward S until it snaps shut. Never switch on with the collet open or in the middle position: the spindle is locked there and the motor will be damaged.
- Bigger heads, lower speed: Foredom's speed chart lowers the top speed as the accessory head gets wider than 3/32" (2 mm).
- Care: clean the collet with a brush or compressed air at least once a week, keep a bur in the collet when it's put away, and rest the handpiece in its cradle so it can't roll off the bench.
- Warranty: the handpiece sold on its own carries Foredom's 90-day limited warranty from the date of purchase. Foredom's 2-year warranty applies to its complete micromotor kits.
Always wear eye protection when operating this handpiece. Wear a dust protector, mask or respirator to avoid inhaling harmful dust or debris from grinding, carving or other operations. Do not wear loose-fitting clothing or jewellery, and secure or tie back long hair. Use only accessories rated for 50,000 rpm or higher with this micromotor. Large burs may begin to vibrate even below their maximum rated speed; reduce the speed immediately to prevent damage to the bur, the handpiece or the operator. Never start the handpiece while the chuck is open (unlocked), as this can damage it. Do not operate the handpiece in the presence of any flammable liquid or gas.